Problem
Some teams accept an A/B test only if the p-value is below the threshold and the observed uplift (the difference of sample means) also exceeds the MDE used to size the sample. An equivalent version recomputes power with the observed uplift in place of the MDE and demands it be at least the planned power. The extra condition looks like a safety check, but it changes the test itself and can make a real effect impossible to confirm.
Example from the article: a test is planned for an assumed effect of 2 with variance 90000, which gives 353304 observations per group. The observed uplift is 1.78 and clears the critical value, yet the "recomputed" power is about 70%, so the rule would reject a result that passed the standard test.
Solution in brief
Treat the MDE, and the power that goes with it, as planning assumptions rather than measurements. Accept the test on the standard criterion only (the observed difference is beyond the critical value, equivalently zero is outside the confidence interval). Judge the size of the effect by the confidence interval, not by power recomputed after the fact.
Questions this case answers
- How to accept or reject a randomized experiment without an extra decision rule that silently destroys statistical power
- How to interpret planned power and the minimum detectable effect after an experiment has finished
- How to decide whether an A/B test is accepted when the observed uplift is smaller than the planned MDE?
- How to report the power of a finished A/B test without misleading the product team?
Tools and methods
- Power analysis — sample size from variance, significance level and an assumed effect (the MDE).
- t-test — the standard acceptance criterion the article defends.
- Monte Carlo simulation — checking empirical power of an acceptance rule against the planned one.