Problem
Compressors, pumps and turbines at petrochemical plants wear out and fail. When a key unit stops, the plant loses millions of rubles a day. With threshold alarms the team learns about a fault late: the bearing is already at 120 °C, production stops, and the crew looks for spare parts under time pressure. Units are unique and failures rare, so there are too few labeled breakdowns to train a classifier.
Example from the article: a bearing normally runs at 65 °C at a given load. A threshold alarm waits for 120 °C. A norm model flags 75 °C, early enough to plan the repair.
Solution in brief
For each unit the system learns normal behavior from months of sensor history and compares live readings with the forecast for a healthy unit. A growing gap raises an alert with priority 1 to 5, and a diagnostics engineer checks neighboring sensors and calls the plant. SIBUR used a Western product from 2019 and now tests its own system built on the same idea.
Questions this case answers
- How to detect early deviation of a machine from its normal operating state when failures are rare and unique to each machine, so supervised failure prediction is not possible
- How to prioritize alerts from an unsupervised anomaly detector so that a human analyst reviews the serious ones first
- How to detect early degradation of a compressor, pump or turbine before an alarm threshold is crossed
- How to build a model of normal behavior for each unit when there are few failures and no labeled breakdowns
Tools and methods
- Similarity-based modeling (SBM) — matrix of 400 normal-state snapshots; forecast of healthy readings
- Autoencoder — under test as a second detector (reconstruction error)
- Vibration spectrum (FFT) — finds defects that overall vibration level hides
- Priority rules 1 to 5 — rank alerts by size and growth of the deviation
- MES or data lake — one place for all sensor readings
Google or a one-time email code. No password.