How we look for equipment defects with ultrasonic microphones

Anna (Vostrikova_av)13 Dec 2022

Problem

On a steel plant's production lines, a worn bearing, a lack of oil or an air leak can stop a whole line, and looking inside a unit means taking half a machine apart. Workers listen through a wooden block that makes ultrasound audible. NLMK IT wanted an objective way to see what is happening in a unit while it is only starting to fail, so that repairs are planned instead of emergency stops.

Example from the article: a roller on the straightening annealing line is recorded from 10–15 meters away, compared with a sample recorded after its last overhaul, and sent for a preventive inspection if the sound has drifted.

Solution in brief

Record each unit for a few minutes with a 49-microphone array and a camera that localizes noise sources in the picture. Compare the recording with a sample of the same unit type recorded just after repair. If the noise leaves the allowed limits, open only that unit and add a confirmed fault's sound to a library.

Questions this case answers
  • How to detect early faults in moving equipment without instrumenting every machine and without opening it, when only a short recording is possible per unit
  • How to turn one-off diagnostic measurements into a repeatable inspection process run by non-specialists
  • How to detect a bearing, gearbox or air-leak defect before the unit breaks without disassembling the machine
  • How to set up an acoustic inspection routine that regular-round staff and contractors can run

Tools and methods

  • Microphone array with camera (49 microphones) — localizes each noise source on the video frame
  • Reference-sample comparison — the post-overhaul recording is the baseline for "normal"
  • Frequency-band reading — 400–10,000 Hz for mechanical faults, above 10,000 Hz for air leaks
  • Library of fault sounds — confirmed defects are saved for matching later recordings