How Machine Vision Watches Over Coke Oven Batteries

WLarsen28 May 2024

Problem

A coke oven battery at NLMK in Lipetsk has 276 ovens and 552 doors. A door that does not seal lets gas escape. It pollutes the city's air and lowers oven efficiency. One door operator per side of the battery had to spot smoke along the whole length. The operator moves 4 meters along the battery with every discharge, so a repeated leak is hard to catch. A removed door can be inspected for only about 2 minutes, while it is very hot and the crew is busy pushing coke. Defects went unnoticed and repair decisions were intuitive, backed by paper logs.

Example from the article: a damaged door frame stayed unnoticed because the door operator covered it during routine work.

Solution in brief

Fixed cameras opposite the doors feed a video analytics platform. A detector fine-tuned on site data outlines smoke, names the door and sends an alert to the cab tablet of the pusher machine, which shortens the time doors leak. The leak counts per door replace intuition when choosing which doors to repair or replace.

Questions this case answers
  • How to detect a short-lived visual event along a long row of identical units when a human walking the row misses it
  • How to turn per-unit event counts from cameras into a repair-or-replace decision when physical inspection time is minutes
  • How to detect gas leaks at coke oven doors automatically with fixed cameras?
  • How to decide which doors to repair or replace when inspection windows last about 2 minutes?

Tools and methods

  • Object detection — finds smoke and its door in each frame.
  • Image segmentation — outlines the smoke area.
  • Manual labeling — tens of thousands of cases sorted by hand for fine-tuning.
  • VideoMatrix Vmx platform — in-house video analytics platform with a base emission detector.